1.The float adopts 304,316 L, TA2 and TC4 material. It has good temperature resistance and can reach to 450℃.
2.The welding process meets the requirements of PED welding process. The chamber is made of 304,316 L. The maximum pressure can reach to 26 MPa.
3.Local indicator type and remote output type with level alarm are optional.
4.According to customer requirements, through a variety of production types, the products can be applied to a variety of working conditions.
1. UHC Magnetic level gauge side-mounted type local indicator
1.1 Side-mounted type magnetic level gauge (normal type)
Scope of application: The level gauge is the most common used side-mounted magnetic level gauge. It is suitable for level or interface measurement with nominal pressure which is not greater than 6.3MPa and the medium temperature is 0℃~+350℃.
Measurement range: 200mm~6000mm (Out of range is acceptable)
Nominal pressure: ≤6.3MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40℃~+80℃
Medium temperature: 0℃≤T<350℃
Accuracy: ±5mm
Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
1.2 Side-mounted type magnetic level gauge (high temperature type)
Scope of application: This type magnetic level gauge is suitable for level or interface measurement in high temperature condition, which nominal pressure is not greater than 6.3 MPa and the medium temperature is 350℃~450℃.
Measurement range: 200mm~6000mm (Out of range is acceptable)
Nominal pressure: ≤6.3MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40℃~+80℃
Medium temperature: 350℃≤T≤450℃
Accuracy: ±5mm
Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
Structure Features: Adopt a high temperature resistant aluminum nickel cobalt magnetic steel + ceramic magnetic column indicator
Side-mounted type magnetic level gauge (high pressure type)
Scope of application: It is suitable for the measurement of level or interface in high-pressure conditions which the maximum nominal pressure is 32MPa, and the medium temperature is 0℃~+450℃
Measurement range: 200mm~6000mm (Out of range is acceptable)
Nominal pressure: ≤32MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40℃~+80℃
Medium temperature: 0℃≤T≤450℃
Accuracy: ±5mm
Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.1g/cm3
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
Side-mounted type magnetic level gauge (Anticorrosive type)
Scope of application: 304 cylinder liner PTFE, is suitable for petroleum, chemical and other industries of strong corrosion medium level or boundary measurement.
Measurement range: 250mm~6500mm (Out of range is acceptable)
Nominal pressure: ≤2.5MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40℃~+80℃
Medium temperature: -50℃≤T≤180℃ (It is related to medium)
Accuracy: ±5mm
Density: Level: ρ≥0.65g/cm3 Interface: ρ1-ρ2≥0.1g/cm3
Wetted material: chamber 304 internal lined with PTFE, float external lined with PTFE
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
Side-mounted type magnetic level gauge (Low temperature type)
Scope of application: It is suitable for measuring level or interface in low temperature and easy frost setting conditions.
Measurement range: 250mm~6500mm
Nominal pressure: ≤16.0MPa
Nominal diameter: DN25 (or on request)
Ambient temperature: -40℃~+80℃
Medium temperature: -40℃~0℃ (Indicator part: Vacuum sealed magnetic flap indicator)
-196℃~-40℃ (Indicator part: Vacuum sealed magnetic flap indicator with frost-proof extension)
Accuracy: ±5mm
Density: Level: ρ≥0.36g/cm3 Interface: ρ1-ρ2≥0.08g/cm3
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
UHC Magnetic level gauge top-mounted type local indicator
Top-mounted type magnetic level gauge (normal type)
Scope of application: Top mounted type. It is suitable for level or interface measurement of various underground storage tanks and containers that are not suitable for opening on the side.
Measurement range: 200mm~4000mm (Out of range is acceptable)
Nominal pressure: ≤5MPa
Nominal diameter: DN150, DN100
Ambient temperature: -40℃~+80℃
Working temperature: -40℃≤T≤+450℃
Accuracy: ±5mm
Density: Level: ρ≥0.45g/cm3 Interface: ρ1-ρ2≥0.16g/cm3
Wetted material: 304, 316L or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or or on request
Top-mounted type magnetic level gauge (Anticorrosive type)
Scope of application: It is suitable for the measurement of level or interface of various underground storage tanks and containers that are not suitable for opening on the side and has strong corrosive medium.
Measurement range: 200mm~4000mm (Out of range is acceptable)
Nominal pressure: ≤5MPa
Nominal diameter: DN150, DN100
Ambient temperature: -40℃~+80℃
Working temperature: -40℃≤T≤+150℃
Accuracy: ±5mm
Density: Level: ρ≥0.7g/cm3 Interface: ρ1-ρ2≥0.16g/cm3
Wetted material: 304+PTFE or on request
Flange standard: HG/T20592-2009,HG/T20615-2009 or on request
Refining: diesel storage tank, catalytic reformers, acid-containing sedimentation tank, hydrocracking, hydrogenation desulfurization, coking unit, solvent extraction, alkylation tank, isomerization, crude oil storage, crude oil desalination, reboiler, distillation tower
Chemical: Demineralized water tank, fermentation tank, chemical reactor, vapor drum in chemical industry, chemical injection, buffer tank, chlor-alkali process, condenser, vapor-liquid separation, liquid ammonia storage, liquid-liquid extraction
Natural Gas: chemical injection, light hydrocarbon recovery, acid gas recovery
Sewage Treatment: plant water
Crude Oil Treatment: crude oil dehydration, drilling fluid storage tank
Electricity: desalination tank, deaerator, power plant vapor drum, feed water heater, boiler sewage tank, lubricating oil tank, flash tank, washing tank, waste heat boiler, pre-flash tank
您的瀏覽器當(dāng)前寬度低于1100px;請(qǐng)使用1300px以上寬度訪(fǎng)問(wèn)。